Horizontal Layout with Flexbox

Gage Selector

Image 1
Image 2
alternative_text alternative_text

Fill in One (only) of The Following Boxes and hit ENTER

For End Connected and Close Hookup Gages, fill in ONE of the two boxes and hit ENTER

Or, for Close Hookup Gages, enter Gage Port C-C, if known, and hit ENTER


USER HAS SELECTED THE OVERRIDE OPTION
Error: Value must be at least 3.75
Error: Value must be at under 159
alternative_text alternative_text

Single Union LG Combo

End Connected Level Gage

Click on a blue Gage Model link to create a datasheet

OPTIONAL Override (End Connected)

This form defaults to the longest LG that will fit within your specified vessel centers. You can select an optional shorter LG in the dropdown below.


USER HAS SELECTED THE OVERRIDE OPTION
#
Gage Model
PSI @ 100°F **
1
2
3
Visible (in)
Min. Vessel C-C (in) ****
LG OAL (in)
Combined Pipe Nipple
Overall Length (in)
Visible (in)
LG OAL (in)
Min. Vessel CC Single Union Valves ****
Min. Vessel CC Double Union Valves ****

** Deratings apply for B7M and B8M bolting and TFE gaskets. Pressure rating limited to 250 WSP for boiler service and 450 WSP for non-boiler steam. Contact factory for boiler service (ASME B&PVC Section I).

*** Minimum recommended combined nipple length = 3" (1-1/2" + 1-1/2"), depends on vessel CC

**** If using Inferno 90° angle gage valves, use these vessel cc dimensions for design purposes.

Warning, 1 - Insulation jackets require 3" minimum upper and lower connecting pipe nipple length (6" total)

Warning, 2 - To avoid interferience with valve handwheel, LG with non-frost extension kit - assembled per orientation FIG 4-1 - requires 2.25" minimum upper and lower connecting pipe nipple length (4.5" total)

Warning, 3 - No-weld bracket kit requires 3.75" minimum length of lower connecting pipe nipple

Warning, 1 - Insulation jackets require 3" minimum upper and lower connecting pipe nipple length (6" total)

Warning, 2 - To avoid interferience with valve handwheel, LG with non-frost extension kit - assembled per orientation FIG 4-1 - requires 2.25" minimum upper and lower connecting pipe nipple length (4.5" total)

Warning, 3a - No-weld bracket kit requires 3.75" minimum length of lower connecting pipe nipple (Single Union)

Warning, 3b - No-weld bracket kit requires 2.25" minimum length of lower connecting pipe nipple (Double Union)

alternative_text alternative_text

Double Union LG Combo

Click on a blue Gage Model link to create a datasheet

OPTIONAL Override (End Connected)

This form defaults to the longest LG that will fit within your specified vessel centers. You can select an optional shorter LG in the dropdown below.


USER HAS SELECTED THE OVERRIDE OPTION
#
Gage Model
PSI @ 100°F **
4
5
6
Visible (in)
Min. Vessel C-C (in) ****
LG OAL (in)
Combined Pipe Nipple
Overall Length (in)

** Deratings apply for B7M and B8M bolting and TFE gaskets. Pressure rating limited to 250 WSP for boiler service and 450 WSP for non-boiler steam. Contact factory for boiler service (ASME B&PVC Section I).

*** Minimum recommended combined nipple length = 3" (1-1/2" + 1-1/2"), depends on vessel CC

Warning, 1 - No-weld bracket kit requires 2.25" minimum length of lower connecting pipe nipple

alternative_text alternative_text

OPTIONAL Override (Close Hookup)

This form defaults to the longest LG that will fit within your specified vessel centers. You can select an optional shorter LG in the dropdown below.

USER HAS SELECTED THE OVERRIDE OPTION

Side Connected Close Hookup Combo

SIDE CONNECTED CLOSE HOOKUP

Click on a blue Gage Model link to create a datasheet
#
Gage Model
Visible (in)
Vessel Connection
Side Ports On Gage Chamber
Gage Port C-C (in)
Vessel C-C (in)
Min. Gage Port C-C (in)
Min. Vessel C-C (in) ****
PSI @ 100°F **
7
8
9
10
11
12

* Additional options available such as ½” M-NPT, 1” M-NPT with Adapter, ANSI Flanged etc. Click a blue Gage Model to further define your requirements and create a data sheet specification.

** Deratings apply for B7M and B8M bolting and TFE gaskets. Pressure rating limited to 250 WSP for boiler service and 450 WSP for non-boiler steam. Contact factory for boiler service (ASME B&PVC Section I).

**** Based on Inferno model FT15, FT25 & 15A offset pattern gage valves, arranged "offsets inside" (three-quarter inch (3/4") offset per valve, 1-1/2" total offset)

alternative_text alternative_text

OPTIONAL Override (Close Hookup)

This form defaults to the longest LG that will fit within your specified vessel centers. You can select an optional shorter LG in the dropdown below.

USER HAS SELECTED THE OVERRIDE OPTION

Back Connected Close Hookup Combo

BACK CONNECTED CLOSE HOOKUP

Click on a blue Gage Model link to create a datasheet
#
Gage Model
Visible (in)
Vessel Connection
Back Ports On Gage Chamber
Gage Port C-C (in)
Vessel C-C (in)
Min. Gage Port C-C (in)
Min. Vessel C-C (in) ****
PSI @ 100°F **
13
14
15
16
17
18

* Additional options available such as ½” M-NPT, 1” M-NPT with Adapter, ANSI Flanged etc. Click a blue Gage Model to further define your requirements and create a data sheet specification.

** Deratings apply for B7M and B8M bolting and TFE gaskets. Pressure rating limited to 250 WSP for boiler service and 450 WSP for non-boiler steam. Contact factory for boiler service (ASME B&PVC Section I).

**** Based on Inferno model FT15, FT25 & 15A offset pattern gage valves, arranged "offsets inside" (three-quarter inch (3/4") offset per valve, 1-1/2" total offset)